| Calibration and testing of: | | Development and production of: | | Monitoring and Measurement of |

 | fLIR test systems |
| |
 | camouflage materials |
| |
 | atmospheric transmission |
|

 | E-O simulators |
| |
 | E-O countermeasures |
| |
 | temprature |
|

 | E-O sources |
| |
 | E-O jammers |
| |
 | emissivity |
|

 | E-O jammers |
| |
 | rocket engines |
| |
 | reflectivity |
|

 | Materials |
| |
 | jet engines |
| |
 | moisture content |
|

| |
 | E-O heat seekers |
| |
 | air pollution |
|

| |
 | E-O sensors |
| |
 | gas burning by-products |
|

|
| ADVANTAGES
 |
|
 | High sensitivity |
| |
 | Wide spectral band (UV to IR) |
| |
 | Wide spectral band (UV to IR) |
|
 | High accuracy |
| |
 | High reliability |
| |
 | Usable in laboratory or field |
|
|
|
FEATURES
 |
|
 | Automatic self calibration |
| |
 | Spectral mode measurements (radiance vs. wavelength) |
| | |
 | Real-time data analysis and display |
| |
 | Radiometric mode measurements (radiance vs. time) |
| | |
 | Rapid scan rates |
| |
 | Full keyboard control |
| | |
 | Flexible software packages |
| |
 | Accurate even for measurement of objects that are at ambient temperatures |
|
 | Computation of calibrated spectra is a matter of seconds |
| | | | |
|
|
SIGNAL PROCESSING
 |
|
 | Signal processing for improved sensitivity |
| |
 | Lowtran software for atmospheric transmittance |
| | |
 | Mathematical computations with spectral data |
| |
 | Spectral emmissivity |
| | |
 | Transient analysis of rapidly occuring events |
| |
 | Effective temperature measurement |
| | |
 | 3-D plots (radiance vs. time and wavelength) |
| |
 | Countermeasures analysis |
| | |
|
|
SPECIFICATIONS
 |
|
| Optics: | | 5" diameter fully reflective telescope f/no=4 (f/no=2 for SR5000W) |

| Focusing range: | | 2.5m to infinity | | |

| Spectral range: | | 0.2 to 25 microns | | |

| Segments spectral resolution | | 2% of wavelength (typical segment dependent) | | |


| Scan rates: | | 0.015 to 30 scans/sec | | |

| Aiming: | | Non parallex though optics on line sighting | | |

| Uniformity of FOV: | | 10% (typically 5%) | | |

| Detector types: | | User interchangeable (even in field) with no need to realign |

| Internal Blackbody: | | At ambient temperature, monitoring accuracy better than 0.1oC | | |

| Chpping Frequency: | | 100 to 1800 Hz. | | |

| Noise performance: | | Wavelength and detector dependent. Example: Maximum 5 mdeg NET with InSb detector and CVF at 5ym, 1Hz bandwidth, 100oC Blackbody filling 6 mrad FOV | |

|
| |